Input Power • Nominal input voltage:120–240V~ • Frequency:50-60Hz • Current consumption,0.3–0.8Afullyloaded Typical: 0.3A(240V~) 0.5A(120V~) • Lightning strike protection meets ANSI/IEEE standard 62.41-1991.Can withstand voltage surges of up to 6000V ~and current surges of up to 500A. • Lightning strike protection meets ANSI/IEEE standard 62.31-1980 when used in a Lutron low-voltage panel (LV16,LV21,PD4-36,PD8-64). Can withstand voltage surges of up to 6000V~ and current surges of up to 3000A. Power Supply Output • Nominal output voltage and tolerance: 24V-/±1% • 1 A SELV/PELV/NECR Class 2 • Power Draw Units (PDUs) : Supplies 30 PDUs maximum*